Modular Gateways

Highlights

 

  • Easy Plug and Play
  • Connection for power supply via screw-type terminal
  • FTP for firmware update
  • Simple plug-in connection by means of plug-in jumper
  • Installation on a DIN rail
  • Galvanised isolation
  • Custom Design versions possible

For several industrial network protocols, including:

Schematic diagram of KUNBUS gateway connecting a PROFIBUS
network to a PROFINET network

Modular Gateway Solution

 

Historically developed networks generally cause problems at some time. Where previously a classical fieldbus like CANopen, PROFIBUS, or DeviceNet was the preferred network, Ethernet-based bus systems are preferred nowadays. However, a protocol change from one fieldbus to another also occurs frequently in practice.

A complete exchange of the communication modules is expensive or often not possible, as the communication circuit board is a part of the control circuit board. So-called gateways were developed as an investment protection. In German they are called “protocol converters”. The gateway compresses all data that the target network can transmit. Furthermore, it drops data that cannot be transmitted or adds required data

Gateways such as the KUNBUS Gateway enable continuous and reliable communication between different networks and systems. The KUNBUS Gateway converts all data that the target network can transfer. It omits non-transferrable data and adds necessary data in the new network. Thus, the operators can transfer all necessary data from one closed network to another.

With this Gateway series KUNBUS offers a protocol converter that can be attached to DIN rails and detached again easily by means of plug and play. The protocols themselves are located in compact modules, whose housings are just 22.5 x 101.4 x 115 in size. The modules are connected via a jumper to a gateway. The user can exchange the protocol modules easily and conveniently to connect one network to another. Customized solutions are also possible. The KUNBUS Gateways are equipped with an integrated web server; program parts are updated via FTP server. The maximum output of the series is three Watt; the voltage tolerance ranges from minus 15 to plus 20 percent.

The modular system allows simple configuration of our Gateways by plug-in linkage or adaption by exchanging the module. By using a jumper you connect two protocolls to a complete gateway.

A big advantage of the KUNBUS Gateways is the reducing of stock-costs. Due to the modular structure you can wait with the configuration till the time of delivery to your customer.

Click & Plug & Play

It cannot be easier.

    Modular Gateway Models

    Protocol PROFINET IRT
    Master/Slave Slave
    Bus connector 2 x RJ45
    Max. baud rate 100 Mbit/s
    I/O Data 512 Bytes IN/OUT
    Protocol EtherNet/IP
    Master/Slave Slave
    Bus connector 2 x RJ45
    Max. baud rate 100 Mbit/s
    I/O Data 480 Bytes IN/OUT
    Protocol POWERLINK
    Master/Slave Slave
    Bus connector 2 x RJ45
    Max. baud rate 100 Mbit/s
    I/O Data 512 Bytes IN/OUT
    Protocol EtherCAT
    Master/Slave Slave
    Bus connector 2 x RJ45
    Max. baud rate 100 Mbit/s
    I/O Data 512 Bytes IN/OUT
    Protocol Sercos III
    Master/Slave Slave
    Bus connector 2 x RJ45
    Max. baud rate 100 Mbit/s
    I/O Data 512 Bytes IN/OUT

     

    Protocol Modbus TCP
    Master/Slave Slave
    Bus connector 2 x RJ45
    Max. baud rate 10/100 Mbit/s
    I/O Data 480 Bytes IN/OUT
    Protocol PROFIBUS
    Master/Slave Slave
    Bus connector D-SUB 9F
    Max. baud rate up to 12 Mbit/s
    I/O Data 244 Bytes IN/OUT
    Protocol DeviceNet
    Master/Slave Slave
    Bus connector 5 pole / pitch 5.08
    Max. baud rate up to 500 Kbit/s
    I/O Data 512 Bytes IN/OUT
    Protocol CANopen
    Master/Slave Slave
    Bus connector D-SUB 9M
    Max. baud rate up to 1 Mbit/s
    I/O Data 512 Bytes IN/OUT
    Protocol Modbus RTU
    Master/Slave Slave
    Bus connector 8 pole / pitch 3.50
    Max. baud rate up to 115.2 Kbit/s
    I/O Data 512 Bytes IN/OUT
    Protocol Serial
    Master/Slave Slave
    Bus connector 8 pole / pitch 3.50
    Max. baud rate up to 115.2 Kbit/s
    I/O Data 512 Bytes IN/OUT
    Protocol DMX
    Master/Slave Master/Slave
    Bus connector 8 pole / pitch 3.50
    Max. baud rate
    I/O Data 512 Bytes IN/OUT
    SPECIFICATIONS
    Power supply 24 V (-15/+20%)
    Max. power 3 W
    Current consumption 100 mA
    Cycle time between two gateway modules 1.2 ms
    Dimensions 22 x 101 x 115 (W x H x D)
    Weight 90g
    Protection Class IP20
    Operationg temperature 0 °C to 60 °C
    Storage temperature -25 °C to 70 °C
    Mounting DIN rail (EN50022)